Elenco dei Decreti - Abilitazioni assegnate da: MINISTERO DELLO SVILUPPO ECONOMICO – MINISTERO DELLE INFRASTRUTTURE – MINISTERO DELL'INTERNO - Ultimo aggiornamento: 2024-01-22
NOTA (*) : uso degli impianti al di fuori del laboratorio notificato (art. 46 Reg. (UE) 305/11)
DecisioneFamiglia di prodotto, prodotto/uso previstoSistema AVCPSpecifica tecnica
98/143/ECSystems of mechanically fastened flexible roof waterproofing membranes including the system of fastening, jointing and edging, and sometimes thermal insulation, limited to continuous watertight systems based on flexible sheets (for roof waterproofing)System 2+EAD 030351-00-0402
2003/655/ECWatertight coverings kits for wetroom floors and walls (1/2) / Watertight covering kits for wetroom floors and walls / for building worksSystem 2+EAD 030352-00-0503
2001/596/ECMembranes (2/3) Damp proofing sheets (for uses subject to reaction to fire regulations)System 1EAD 030400-00-0605
2001/596/ECMembranes (1/3) Damp proofing sheets (in buildings)System 2+EAD 030400-00-0605
2003/655/ECWatertight covering kits based on flexible sheets for wet room floors and or wallsSystem 2+EAD 030436-00-0503
2003/655/ECWatertight covering kits based on inherently watertight boards for wet room floors and or wallsSystem 2+EAD 030437-00-0503
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations); • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)System 1EAD 040016-01-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations); External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)System 2+EAD 040016-01-0404
97/556/ECExternal thermal insulation composite systems (ETICS) with renderings: • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)System 1EAD 040083-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)System 2+EAD 040083-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External Thermal Insulation Composite Systems with renderings for the use on timber frame buildings (in external wall subject to fire regulations)System 1EAD 040089-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External Thermal Insulation Composite Systems with renderings for the use on timber frame buildings (in external wall not subject to fire regulations)System 2+EAD 040089-00-0404
99/91/ECThermal insulating products (factory-made products and products intended to be formed insitu) (for uses subject to regulations on reaction to fireSystem 1EAD 040138-00-1201
97/556/ECKits for external thermal insulation composite system (ETICS) with panels as thermal insulation product and discontinuous claddings as exteriorSystem 1EAD 040287-00-0404
97/556/ECKits for external thermal insulation composite system (ETICS) with panels as thermal insulation product and discontinuous claddings as exterior skinSystem 2+EAD 040287-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1) External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulationsSystem 1EAD 040465-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1) External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)System 2+EAD 040465-00-0404
95/467/ECStructural bearings (1/1): Spherical and cylindrical bearing with special sliding material made of UHMWPE (Ultra high molecular weight poyethylene) (in buildings and civil engineering works where requirements on individual bearings are critical)System 1EAD 050004-00-0301
2003/648/ECKits for external wall claddings mechanically fixed (for uses subject to regulations on reaction to fire)System 1EAD 090062-00-0404
2003/648/ECKits for external wall claddings mechanically fixed (for external walls or external finishes of walls)System 2+EAD 090062-00-0404
2003/640/ECKits for exterior wall claddings (2/2) Kits for exterior wall claddings (for uses subject to regulations on reaction to fire)System 1EAD 090119-00-0404
2003/640/ECKits for exterior wall claddings (1/2) Kits for exterior wall claddings (for external walls or external finishes of walls)System 2+EAD 090119-00-0404
2001/19/ECNosing expansion joints for road bridgesSystem 1EAD 120109-00-0107
2001/19/ECMat expansion joints for road bridgesSystem 1EAD 120110-00-0107
2001/19/ECFlexible plug expansion joints for road bridges with flexible filling based on a synthetic polymer as binder (in road bridges)System 1EAD 120111-00-0107
2001/19/ECSupported expansion joints for road bridgesSystem 1EAD 120112-00-0107
97/638/ECFasteners for structural timber products (1/1): - Shear plates (for structural timber products)System 2+EAD 130186-00-0603
97/555/ECRapid hardening sulfate resistant calcium sulphoaluminate based cement (preparation of concrete, mortar, grout and other mixes for construction and for the manufacture of construction products)System 1+EAD 150004-00-0301
2000/606/ECNon-screwable sleeve for mechanical splices by lateral compression of reinforcing barsSystem 1+EAD 160124-00-0301
98/214/ECStructural metallic products and ancillaries (2/4): Weldmesh gabion boxes and mattresses (for uses in work's frames and foundations)System 2+EAD 200020-00-0102
98/214/ECSteel components for pallet racking systems (to be used in metal structures or in composite metal and concrete structures)System 2+EAD 200059-00-0302
98/213/ECInternal partition kits (for uses subject to reaction to fire requirements)System 1EAD 210005-00-0505
2003/656/ECSingle point supported vertical glazing (EOTA ref. 04.04/25) (in building works)System 1EAD 220025-00-0401
97/587/ECStructural sections made from fibre reinforced polymers (FRP/Glassfiber Composites) (used for the reinforcement of concrete)System 1+EAD 260001-00-0303
99/469/ECNatural calcined pozzolana as type II addition for concrete for concrete, mortar and groutSystem 1+EAD 260035-00-0301
97/463/ECChannel bars (EOTA 06.01/01) (for anchoring uses)System 1EAD 330008-03-0601
97/161/ECFastener of external wall claddings (for use in reduntant systems for fixing and/or supporting to concrete elements such as lightweight suspended ceilings, as well as installations)System 2+EAD 330030-00-0601
97/463/ECPlastic anchors for fixing of external thermal insulation composite systems (ETICS) with rendering (for use in systems, such as faSystem 2+EAD 330196-00-0604
97/463/ECPlastic anchors for use in concrete and masonry (for use in systems, such as facade systems, for fixing or supporting elements which contribute to the stability of the systems)System 2+EAD 330284-00-0604
97/463/ECPoint connector of glass fibre reinforced polymer for sandwich walls (for use in systems, such as faSystem 2+EAD 330389-00-0601
97/463/ECGlass, basalt, aramid, carbon, PBO (polyparaphenylene benzobisoxazole) and steel rovings for fibre-reinforced anchor spikesSystem 2+EAD 331668-00-0104
2003/728/ECMetal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits :• Concrete frame building kits (in building works)System 1EAD 340002-00-0204
99/89/ECPrefabricated stair kits / for uses subject to reaction to fire regulationsSystem 1EAD 340006-00-0506
99/89/ECPrefabricated stair kits (1/2) : • Prefabricated stair kits (for dwellings and other buildings)System 2+EAD 340006-00-0506
99/469/ECSRP (Steel Reinforced Polymer) kit made of steel micro-wires, fiberglass mesh and epoxy adhesive (for concrete, mortar and grout)System 2+EAD 340210-00-0104
99/597/ECExternally-bonded composite systems with inorganic matrix for strengthening of concrete and masonry structuresSystem 2+EAD 340275-00-0104
2003/728/ECReinforced high density EPS structural panel system for building unitsSystem 1EAD 340287-00-0203
99/495/ECTimber building kitsSystem 1EAD 340308-00-0203
98/279/ECNon load- bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings); Non load- bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: panels made of an insulating material (or a combination of an insulating material and other materials), consisting of shuttering leaves linked by spacers (for the construction of external and internal walls not subject to fire regulations, in buildings)System 1EAD 340309-00-0305
98/279/ECNon load- bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)System 2+EAD 340309-00-0305
2003/728/ECModular pre-fabricated cemetery construction structureSystem 1EAD 340383-00-0203
99/597/ECCRM (Composite Reinforced Mortar) Systems for strengthening concrete and masonry structuresSystem 2+EAD 340392-00-0104
97/555/ECHydraulic road binders - Part 1: Rapid hardening hydraulic road binders - Composition, specifications and conformity criteriaSystem 2+EN 13282-1:2013
0Reaction to fire0EN 13823
96/580/ECCurtain wallings (1/1) : • Curtain wall kits (as external walls not subject to reaction to fire requirements)System 3EN 13830:2003(*)
97/555/CECement - Composition, specifications and conformity criteria for very low heat special cementsSystem 1+EN 14216:2015
99/93/ECDoors, windows, shutters, blinds, gates and related building hardware (1/1) : • Windows (with or without related hardware) (any other); • Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))System 3EN 14351-1:2006+A1:2010(*) EN 14351-1:2006+A2:2016
97/555/ECCements, building limes and other hydraulic binders : • Hydraulic road binders (preparation of concrete, mortar, grout and other mixes for road bases stabilisation)System 2+EN 15368:2008+A1:2010
97/555/ECCement - Part 1: Composition, specifications and conformity criteria for common cementsSystem 1+EN 197-1:2011
97/555/ECMasonry cement - Part 1: Composition, specifications and conformity criteriaSystem 1+EN 413-1:2011
97/740/ECSpecification for mortar for masonry - Part 2: Masonry mortarSystem 2+EN 998-2:2016
Sound absorptionEN ISO 10140-1
Reaction to fireEN ISO 1182
Reaction to fireEN ISO 11925-2
Reaction to fireEN ISO 1716
Sound absorptionEN ISO 354
Reaction to fireEN ISO 9239-1
Sound InsulationEN ISO 717-1:2020
DecisioneFamiglia di prodotto, prodotto/uso previstoSistema AVCPSpecifica tecnica
98/143/ECSystems of mechanically fastened flexible roof waterproofing membranes including the system of fastening, jointing and edging, and sometimes thermal insulation, limited to continuous watertight systems based on flexible sheets (for roof waterproofing)System 2+EAD 030351-00-0402
2003/655/ECWatertight coverings kits for wetroom floors and walls (1/2) / Watertight covering kits for wetroom floors and walls / for building worksSystem 2+EAD 030352-00-0503
2001/596/ECMembranes (2/3) Damp proofing sheets (for uses subject to reaction to fire regulations)System 1EAD 030400-00-0605
2001/596/ECMembranes (1/3) Damp proofing sheets (in buildings)System 2+EAD 030400-00-0605
2003/655/ECWatertight covering kits based on flexible sheets for wet room floors and or wallsSystem 2+EAD 030436-00-0503
2003/655/ECWatertight covering kits based on inherently watertight boards for wet room floors and or wallsSystem 2+EAD 030437-00-0503
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations); • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)System 1EAD 040016-01-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations); External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)System 2+EAD 040016-01-0404
97/556/ECExternal thermal insulation composite systems (ETICS) with renderings: • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)System 1EAD 040083-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)System 2+EAD 040083-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External Thermal Insulation Composite Systems with renderings for the use on timber frame buildings (in external wall subject to fire regulations)System 1EAD 040089-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External Thermal Insulation Composite Systems with renderings for the use on timber frame buildings (in external wall not subject to fire regulations)System 2+EAD 040089-00-0404
99/91/ECThermal insulating products (factory-made products and products intended to be formed insitu) (for uses subject to regulations on reaction to fireSystem 1EAD 040138-00-1201
97/556/ECKits for external thermal insulation composite system (ETICS) with panels as thermal insulation product and discontinuous claddings as exteriorSystem 1EAD 040287-00-0404
97/556/ECKits for external thermal insulation composite system (ETICS) with panels as thermal insulation product and discontinuous claddings as exterior skinSystem 2+EAD 040287-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1) External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulationsSystem 1EAD 040465-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1) External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)System 2+EAD 040465-00-0404
95/467/ECStructural bearings (1/1): Spherical and cylindrical bearing with special sliding material made of UHMWPE (Ultra high molecular weight poyethylene) (in buildings and civil engineering works where requirements on individual bearings are critical)System 1EAD 050004-00-0301
2003/648/ECKits for external wall claddings mechanically fixed (for uses subject to regulations on reaction to fire)System 1EAD 090062-00-0404
2003/648/ECKits for external wall claddings mechanically fixed (for external walls or external finishes of walls)System 2+EAD 090062-00-0404
2003/640/ECKits for exterior wall claddings (2/2) Kits for exterior wall claddings (for uses subject to regulations on reaction to fire)System 1EAD 090119-00-0404
2003/640/ECKits for exterior wall claddings (1/2) Kits for exterior wall claddings (for external walls or external finishes of walls)System 2+EAD 090119-00-0404
2001/19/ECNosing expansion joints for road bridgesSystem 1EAD 120109-00-0107
2001/19/ECMat expansion joints for road bridgesSystem 1EAD 120110-00-0107
2001/19/ECFlexible plug expansion joints for road bridges with flexible filling based on a synthetic polymer as binder (in road bridges)System 1EAD 120111-00-0107
2001/19/ECSupported expansion joints for road bridgesSystem 1EAD 120112-00-0107
97/638/ECFasteners for structural timber products (1/1): - Shear plates (for structural timber products)System 2+EAD 130186-00-0603
97/555/ECRapid hardening sulfate resistant calcium sulphoaluminate based cement (preparation of concrete, mortar, grout and other mixes for construction and for the manufacture of construction products)System 1+EAD 150004-00-0301
2000/606/ECNon-screwable sleeve for mechanical splices by lateral compression of reinforcing barsSystem 1+EAD 160124-00-0301
98/214/ECStructural metallic products and ancillaries (2/4): Weldmesh gabion boxes and mattresses (for uses in work's frames and foundations)System 2+EAD 200020-00-0102
98/214/ECSteel components for pallet racking systems (to be used in metal structures or in composite metal and concrete structures)System 2+EAD 200059-00-0302
98/213/ECInternal partition kits (for uses subject to reaction to fire requirements)System 1EAD 210005-00-0505
2003/656/ECSingle point supported vertical glazing (EOTA ref. 04.04/25) (in building works)System 1EAD 220025-00-0401
97/587/ECStructural sections made from fibre reinforced polymers (FRP/Glassfiber Composites) (used for the reinforcement of concrete)System 1+EAD 260001-00-0303
99/469/ECNatural calcined pozzolana as type II addition for concrete for concrete, mortar and groutSystem 1+EAD 260035-00-0301
97/463/ECChannel bars (EOTA 06.01/01) (for anchoring uses)System 1EAD 330008-03-0601
97/161/ECFastener of external wall claddings (for use in reduntant systems for fixing and/or supporting to concrete elements such as lightweight suspended ceilings, as well as installations)System 2+EAD 330030-00-0601
97/463/ECPlastic anchors for fixing of external thermal insulation composite systems (ETICS) with rendering (for use in systems, such as faSystem 2+EAD 330196-00-0604
97/463/ECPlastic anchors for use in concrete and masonry (for use in systems, such as facade systems, for fixing or supporting elements which contribute to the stability of the systems)System 2+EAD 330284-00-0604
97/463/ECPoint connector of glass fibre reinforced polymer for sandwich walls (for use in systems, such as faSystem 2+EAD 330389-00-0601
97/463/ECGlass, basalt, aramid, carbon, PBO (polyparaphenylene benzobisoxazole) and steel rovings for fibre-reinforced anchor spikesSystem 2+EAD 331668-00-0104
2003/728/ECMetal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits :• Concrete frame building kits (in building works)System 1EAD 340002-00-0204
99/89/ECPrefabricated stair kits / for uses subject to reaction to fire regulationsSystem 1EAD 340006-00-0506
99/89/ECPrefabricated stair kits (1/2) : • Prefabricated stair kits (for dwellings and other buildings)System 2+EAD 340006-00-0506
99/469/ECSRP (Steel Reinforced Polymer) kit made of steel micro-wires, fiberglass mesh and epoxy adhesive (for concrete, mortar and grout)System 2+EAD 340210-00-0104
99/597/ECExternally-bonded composite systems with inorganic matrix for strengthening of concrete and masonry structuresSystem 2+EAD 340275-00-0104
2003/728/ECReinforced high density EPS structural panel system for building unitsSystem 1EAD 340287-00-0203
99/495/ECTimber building kitsSystem 1EAD 340308-00-0203
98/279/ECNon load- bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings); Non load- bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: panels made of an insulating material (or a combination of an insulating material and other materials), consisting of shuttering leaves linked by spacers (for the construction of external and internal walls not subject to fire regulations, in buildings)System 1EAD 340309-00-0305
98/279/ECNon load- bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)System 2+EAD 340309-00-0305
2003/728/ECModular pre-fabricated cemetery construction structureSystem 1EAD 340383-00-0203
99/597/ECCRM (Composite Reinforced Mortar) Systems for strengthening concrete and masonry structuresSystem 2+EAD 340392-00-0104
97/555/ECHydraulic road binders - Part 1: Rapid hardening hydraulic road binders - Composition, specifications and conformity criteriaSystem 2+EN 13282-1:2013
0Reaction to fire0EN 13823
96/580/ECCurtain wallings (1/1) : • Curtain wall kits (as external walls not subject to reaction to fire requirements)System 3EN 13830:2003(*)
97/555/CECement - Composition, specifications and conformity criteria for very low heat special cementsSystem 1+EN 14216:2015
99/93/ECDoors, windows, shutters, blinds, gates and related building hardware (1/1) : • Windows (with or without related hardware) (any other); • Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))System 3EN 14351-1:2006+A1:2010(*) EN 14351-1:2006+A2:2016
97/555/ECCements, building limes and other hydraulic binders : • Hydraulic road binders (preparation of concrete, mortar, grout and other mixes for road bases stabilisation)System 2+EN 15368:2008+A1:2010
97/555/ECCement - Part 1: Composition, specifications and conformity criteria for common cementsSystem 1+EN 197-1:2011
97/555/ECMasonry cement - Part 1: Composition, specifications and conformity criteriaSystem 1+EN 413-1:2011
97/740/ECSpecification for mortar for masonry - Part 2: Masonry mortarSystem 2+EN 998-2:2016
Sound absorptionEN ISO 10140-1
Reaction to fireEN ISO 1182
Reaction to fireEN ISO 11925-2
Reaction to fireEN ISO 1716
Sound absorptionEN ISO 354
Reaction to fireEN ISO 9239-1
Sound InsulationEN ISO 717-1:2020
DecisioneFamiglia di prodotto, prodotto/uso previstoSistema AVCPSpecifica tecnica
98/143/ECSystems of mechanically fastened flexible roof waterproofing membranes including the system of fastening, jointing and edging, and sometimes thermal insulation, limited to continuous watertight systems based on flexible sheets (for roof waterproofing)System 2+EAD 030351-00-0402
2003/655/ECWatertight coverings kits for wetroom floors and walls (1/2) / Watertight covering kits for wetroom floors and walls / for building worksSystem 2+EAD 030352-00-0503
2001/596/ECMembranes (2/3) Damp proofing sheets (for uses subject to reaction to fire regulations)System 1EAD 030400-00-0605
2001/596/ECMembranes (1/3) Damp proofing sheets (in buildings)System 2+EAD 030400-00-0605
2003/655/ECWatertight covering kits based on flexible sheets for wet room floors and or wallsSystem 2+EAD 030436-00-0503
2003/655/ECWatertight covering kits based on inherently watertight boards for wet room floors and or wallsSystem 2+EAD 030437-00-0503
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations); • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)System 1EAD 040016-01-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations); External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)System 2+EAD 040016-01-0404
97/556/ECExternal thermal insulation composite systems (ETICS) with renderings: • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)System 1EAD 040083-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)System 2+EAD 040083-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External Thermal Insulation Composite Systems with renderings for the use on timber frame buildings (in external wall subject to fire regulations)System 1EAD 040089-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External Thermal Insulation Composite Systems with renderings for the use on timber frame buildings (in external wall not subject to fire regulations)System 2+EAD 040089-00-0404
99/91/ECThermal insulating products (factory-made products and products intended to be formed insitu) (for uses subject to regulations on reaction to fireSystem 1EAD 040138-00-1201
97/556/ECKits for external thermal insulation composite system (ETICS) with panels as thermal insulation product and discontinuous claddings as exteriorSystem 1EAD 040287-00-0404
97/556/ECKits for external thermal insulation composite system (ETICS) with panels as thermal insulation product and discontinuous claddings as exterior skinSystem 2+EAD 040287-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1) External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulationsSystem 1EAD 040465-00-0404
97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1) External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)System 2+EAD 040465-00-0404
95/467/ECStructural bearings (1/1): Spherical and cylindrical bearing with special sliding material made of UHMWPE (Ultra high molecular weight poyethylene) (in buildings and civil engineering works where requirements on individual bearings are critical)System 1EAD 050004-00-0301
2003/648/ECKits for external wall claddings mechanically fixed (for uses subject to regulations on reaction to fire)System 1EAD 090062-00-0404
2003/648/ECKits for external wall claddings mechanically fixed (for external walls or external finishes of walls)System 2+EAD 090062-00-0404
2003/640/ECKits for exterior wall claddings (2/2) Kits for exterior wall claddings (for uses subject to regulations on reaction to fire)System 1EAD 090119-00-0404
2003/640/ECKits for exterior wall claddings (1/2) Kits for exterior wall claddings (for external walls or external finishes of walls)System 2+EAD 090119-00-0404
2001/19/ECNosing expansion joints for road bridgesSystem 1EAD 120109-00-0107
2001/19/ECMat expansion joints for road bridgesSystem 1EAD 120110-00-0107
2001/19/ECFlexible plug expansion joints for road bridges with flexible filling based on a synthetic polymer as binder (in road bridges)System 1EAD 120111-00-0107
2001/19/ECSupported expansion joints for road bridgesSystem 1EAD 120112-00-0107
97/638/ECFasteners for structural timber products (1/1): - Shear plates (for structural timber products)System 2+EAD 130186-00-0603
97/555/ECRapid hardening sulfate resistant calcium sulphoaluminate based cement (preparation of concrete, mortar, grout and other mixes for construction and for the manufacture of construction products)System 1+EAD 150004-00-0301
2000/606/ECNon-screwable sleeve for mechanical splices by lateral compression of reinforcing barsSystem 1+EAD 160124-00-0301
98/214/ECStructural metallic products and ancillaries (2/4): Weldmesh gabion boxes and mattresses (for uses in work's frames and foundations)System 2+EAD 200020-00-0102
98/214/ECSteel components for pallet racking systems (to be used in metal structures or in composite metal and concrete structures)System 2+EAD 200059-00-0302
98/213/ECInternal partition kits (for uses subject to reaction to fire requirements)System 1EAD 210005-00-0505
2003/656/ECSingle point supported vertical glazing (EOTA ref. 04.04/25) (in building works)System 1EAD 220025-00-0401
97/587/ECStructural sections made from fibre reinforced polymers (FRP/Glassfiber Composites) (used for the reinforcement of concrete)System 1+EAD 260001-00-0303
99/469/ECNatural calcined pozzolana as type II addition for concrete for concrete, mortar and groutSystem 1+EAD 260035-00-0301
97/463/ECChannel bars (EOTA 06.01/01) (for anchoring uses)System 1EAD 330008-03-0601
97/161/ECFastener of external wall claddings (for use in reduntant systems for fixing and/or supporting to concrete elements such as lightweight suspended ceilings, as well as installations)System 2+EAD 330030-00-0601
97/463/ECPlastic anchors for fixing of external thermal insulation composite systems (ETICS) with rendering (for use in systems, such as faSystem 2+EAD 330196-00-0604
97/463/ECPlastic anchors for use in concrete and masonry (for use in systems, such as facade systems, for fixing or supporting elements which contribute to the stability of the systems)System 2+EAD 330284-00-0604
97/463/ECPoint connector of glass fibre reinforced polymer for sandwich walls (for use in systems, such as faSystem 2+EAD 330389-00-0601
97/463/ECGlass, basalt, aramid, carbon, PBO (polyparaphenylene benzobisoxazole) and steel rovings for fibre-reinforced anchor spikesSystem 2+EAD 331668-00-0104
2003/728/ECMetal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits :• Concrete frame building kits (in building works)System 1EAD 340002-00-0204
99/89/ECPrefabricated stair kits / for uses subject to reaction to fire regulationsSystem 1EAD 340006-00-0506
99/89/ECPrefabricated stair kits (1/2) : • Prefabricated stair kits (for dwellings and other buildings)System 2+EAD 340006-00-0506
99/469/ECSRP (Steel Reinforced Polymer) kit made of steel micro-wires, fiberglass mesh and epoxy adhesive (for concrete, mortar and grout)System 2+EAD 340210-00-0104
99/597/ECExternally-bonded composite systems with inorganic matrix for strengthening of concrete and masonry structuresSystem 2+EAD 340275-00-0104
2003/728/ECReinforced high density EPS structural panel system for building unitsSystem 1EAD 340287-00-0203
99/495/ECTimber building kitsSystem 1EAD 340308-00-0203
98/279/ECNon load- bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings); Non load- bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: panels made of an insulating material (or a combination of an insulating material and other materials), consisting of shuttering leaves linked by spacers (for the construction of external and internal walls not subject to fire regulations, in buildings)System 1EAD 340309-00-0305
98/279/ECNon load- bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)System 2+EAD 340309-00-0305
2003/728/ECModular pre-fabricated cemetery construction structureSystem 1EAD 340383-00-0203
99/597/ECCRM (Composite Reinforced Mortar) Systems for strengthening concrete and masonry structuresSystem 2+EAD 340392-00-0104
97/555/ECHydraulic road binders - Part 1: Rapid hardening hydraulic road binders - Composition, specifications and conformity criteriaSystem 2+EN 13282-1:2013
0Reaction to fire0EN 13823
96/580/ECCurtain wallings (1/1) : • Curtain wall kits (as external walls not subject to reaction to fire requirements)System 3EN 13830:2003(*)
97/555/CECement - Composition, specifications and conformity criteria for very low heat special cementsSystem 1+EN 14216:2015
99/93/ECDoors, windows, shutters, blinds, gates and related building hardware (1/1) : • Windows (with or without related hardware) (any other); • Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))System 3EN 14351-1:2006+A1:2010(*) EN 14351-1:2006+A2:2016
97/555/ECCements, building limes and other hydraulic binders : • Hydraulic road binders (preparation of concrete, mortar, grout and other mixes for road bases stabilisation)System 2+EN 15368:2008+A1:2010
97/555/ECCement - Part 1: Composition, specifications and conformity criteria for common cementsSystem 1+EN 197-1:2011
97/555/ECMasonry cement - Part 1: Composition, specifications and conformity criteriaSystem 1+EN 413-1:2011
97/740/ECSpecification for mortar for masonry - Part 2: Masonry mortarSystem 2+EN 998-2:2016
Sound absorptionEN ISO 10140-1
Reaction to fireEN ISO 1182
Reaction to fireEN ISO 11925-2
Reaction to fireEN ISO 1716
Sound absorptionEN ISO 354
Reaction to fireEN ISO 9239-1
Sound InsulationEN ISO 717-1:2020
DecisioneFamiglia di prodotto, prodotto/uso previstoAltri dati
98/143/ECSystems of mechanically fastened flexible roof waterproofing membranes including the system of fastening, jointing and edging, and sometimes thermal insulation, limited to continuous watertight systems based on flexible sheets (for roof waterproofing)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 030351-00-0402

2003/655/ECWatertight coverings kits for wetroom floors and walls (1/2) / Watertight covering kits for wetroom floors and walls / for building worksvedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 030352-00-0503

2001/596/ECMembranes (2/3) Damp proofing sheets (for uses subject to reaction to fire regulations)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 030400-00-0605

2001/596/ECMembranes (1/3) Damp proofing sheets (in buildings)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 030400-00-0605

2003/655/ECWatertight covering kits based on flexible sheets for wet room floors and or wallsvedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 030436-00-0503

2003/655/ECWatertight covering kits based on inherently watertight boards for wet room floors and or wallsvedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 030437-00-0503

97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations); • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 040016-01-0404

97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations); External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 040016-01-0404

97/556/ECExternal thermal insulation composite systems (ETICS) with renderings: • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 040083-00-0404

97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 040083-00-0404

97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External Thermal Insulation Composite Systems with renderings for the use on timber frame buildings (in external wall subject to fire regulations)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 040089-00-0404

97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1): • External Thermal Insulation Composite Systems with renderings for the use on timber frame buildings (in external wall not subject to fire regulations)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 040089-00-0404

99/91/ECThermal insulating products (factory-made products and products intended to be formed insitu) (for uses subject to regulations on reaction to firevedi

Sistema AVCP: System 1

Specifica tecnica: EAD 040138-00-1201

97/556/ECKits for external thermal insulation composite system (ETICS) with panels as thermal insulation product and discontinuous claddings as exteriorvedi

Sistema AVCP: System 1

Specifica tecnica: EAD 040287-00-0404

97/556/ECKits for external thermal insulation composite system (ETICS) with panels as thermal insulation product and discontinuous claddings as exterior skinvedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 040287-00-0404

97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1) External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulationsvedi

Sistema AVCP: System 1

Specifica tecnica: EAD 040465-00-0404

97/556/ECExternal thermal insulation composite systems/kits with rendering (ETICS)(1/1) External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 040465-00-0404

95/467/ECStructural bearings (1/1): Spherical and cylindrical bearing with special sliding material made of UHMWPE (Ultra high molecular weight poyethylene) (in buildings and civil engineering works where requirements on individual bearings are critical)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 050004-00-0301

2003/648/ECKits for external wall claddings mechanically fixed (for uses subject to regulations on reaction to fire)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 090062-00-0404

2003/648/ECKits for external wall claddings mechanically fixed (for external walls or external finishes of walls)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 090062-00-0404

2003/640/ECKits for exterior wall claddings (2/2) Kits for exterior wall claddings (for uses subject to regulations on reaction to fire)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 090119-00-0404

2003/640/ECKits for exterior wall claddings (1/2) Kits for exterior wall claddings (for external walls or external finishes of walls)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 090119-00-0404

2001/19/ECNosing expansion joints for road bridgesvedi

Sistema AVCP: System 1

Specifica tecnica: EAD 120109-00-0107

2001/19/ECMat expansion joints for road bridgesvedi

Sistema AVCP: System 1

Specifica tecnica: EAD 120110-00-0107

2001/19/ECFlexible plug expansion joints for road bridges with flexible filling based on a synthetic polymer as binder (in road bridges)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 120111-00-0107

2001/19/ECSupported expansion joints for road bridgesvedi

Sistema AVCP: System 1

Specifica tecnica: EAD 120112-00-0107

97/638/ECFasteners for structural timber products (1/1): - Shear plates (for structural timber products)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 130186-00-0603

97/555/ECRapid hardening sulfate resistant calcium sulphoaluminate based cement (preparation of concrete, mortar, grout and other mixes for construction and for the manufacture of construction products)vedi

Sistema AVCP: System 1+

Specifica tecnica: EAD 150004-00-0301

2000/606/ECNon-screwable sleeve for mechanical splices by lateral compression of reinforcing barsvedi

Sistema AVCP: System 1+

Specifica tecnica: EAD 160124-00-0301

98/214/ECStructural metallic products and ancillaries (2/4): Weldmesh gabion boxes and mattresses (for uses in work's frames and foundations)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 200020-00-0102

98/214/ECSteel components for pallet racking systems (to be used in metal structures or in composite metal and concrete structures)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 200059-00-0302

98/213/ECInternal partition kits (for uses subject to reaction to fire requirements)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 210005-00-0505

2003/656/ECSingle point supported vertical glazing (EOTA ref. 04.04/25) (in building works)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 220025-00-0401

97/587/ECStructural sections made from fibre reinforced polymers (FRP/Glassfiber Composites) (used for the reinforcement of concrete)vedi

Sistema AVCP: System 1+

Specifica tecnica: EAD 260001-00-0303

99/469/ECNatural calcined pozzolana as type II addition for concrete for concrete, mortar and groutvedi

Sistema AVCP: System 1+

Specifica tecnica: EAD 260035-00-0301

97/463/ECChannel bars (EOTA 06.01/01) (for anchoring uses)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 330008-03-0601

97/161/ECFastener of external wall claddings (for use in reduntant systems for fixing and/or supporting to concrete elements such as lightweight suspended ceilings, as well as installations)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 330030-00-0601

97/463/ECPlastic anchors for fixing of external thermal insulation composite systems (ETICS) with rendering (for use in systems, such as favedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 330196-00-0604

97/463/ECPlastic anchors for use in concrete and masonry (for use in systems, such as facade systems, for fixing or supporting elements which contribute to the stability of the systems)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 330284-00-0604

97/463/ECPoint connector of glass fibre reinforced polymer for sandwich walls (for use in systems, such as favedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 330389-00-0601

97/463/ECGlass, basalt, aramid, carbon, PBO (polyparaphenylene benzobisoxazole) and steel rovings for fibre-reinforced anchor spikesvedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 331668-00-0104

2003/728/ECMetal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits :• Concrete frame building kits (in building works)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 340002-00-0204

99/89/ECPrefabricated stair kits / for uses subject to reaction to fire regulationsvedi

Sistema AVCP: System 1

Specifica tecnica: EAD 340006-00-0506

99/89/ECPrefabricated stair kits (1/2) : • Prefabricated stair kits (for dwellings and other buildings)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 340006-00-0506

99/469/ECSRP (Steel Reinforced Polymer) kit made of steel micro-wires, fiberglass mesh and epoxy adhesive (for concrete, mortar and grout)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 340210-00-0104

99/597/ECExternally-bonded composite systems with inorganic matrix for strengthening of concrete and masonry structuresvedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 340275-00-0104

2003/728/ECReinforced high density EPS structural panel system for building unitsvedi

Sistema AVCP: System 1

Specifica tecnica: EAD 340287-00-0203

99/495/ECTimber building kitsvedi

Sistema AVCP: System 1

Specifica tecnica: EAD 340308-00-0203

98/279/ECNon load- bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings); Non load- bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: panels made of an insulating material (or a combination of an insulating material and other materials), consisting of shuttering leaves linked by spacers (for the construction of external and internal walls not subject to fire regulations, in buildings)vedi

Sistema AVCP: System 1

Specifica tecnica: EAD 340309-00-0305

98/279/ECNon load- bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)vedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 340309-00-0305

2003/728/ECModular pre-fabricated cemetery construction structurevedi

Sistema AVCP: System 1

Specifica tecnica: EAD 340383-00-0203

99/597/ECCRM (Composite Reinforced Mortar) Systems for strengthening concrete and masonry structuresvedi

Sistema AVCP: System 2+

Specifica tecnica: EAD 340392-00-0104

97/555/ECHydraulic road binders - Part 1: Rapid hardening hydraulic road binders - Composition, specifications and conformity criteriavedi

Sistema AVCP: System 2+

Specifica tecnica: EN 13282-1:2013

0Reaction to firevedi

Sistema AVCP: 0

Specifica tecnica: EN 13823

96/580/ECCurtain wallings (1/1) : • Curtain wall kits (as external walls not subject to reaction to fire requirements)vedi

Sistema AVCP: System 3

Specifica tecnica: EN 13830:2003(*)

97/555/CECement - Composition, specifications and conformity criteria for very low heat special cementsvedi

Sistema AVCP: System 1+

Specifica tecnica: EN 14216:2015

99/93/ECDoors, windows, shutters, blinds, gates and related building hardware (1/1) : • Windows (with or without related hardware) (any other); • Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))vedi

Sistema AVCP: System 3

Specifica tecnica: EN 14351-1:2006+A1:2010(*) EN 14351-1:2006+A2:2016

97/555/ECCements, building limes and other hydraulic binders : • Hydraulic road binders (preparation of concrete, mortar, grout and other mixes for road bases stabilisation)vedi

Sistema AVCP: System 2+

Specifica tecnica: EN 15368:2008+A1:2010

97/555/ECCement - Part 1: Composition, specifications and conformity criteria for common cementsvedi

Sistema AVCP: System 1+

Specifica tecnica: EN 197-1:2011

97/555/ECMasonry cement - Part 1: Composition, specifications and conformity criteriavedi

Sistema AVCP: System 1+

Specifica tecnica: EN 413-1:2011

97/740/ECSpecification for mortar for masonry - Part 2: Masonry mortarvedi

Sistema AVCP: System 2+

Specifica tecnica: EN 998-2:2016

Sound absorptionvedi

Sistema AVCP:

Specifica tecnica: EN ISO 10140-1

Reaction to firevedi

Sistema AVCP:

Specifica tecnica: EN ISO 1182

Reaction to firevedi

Sistema AVCP:

Specifica tecnica: EN ISO 11925-2

Reaction to firevedi

Sistema AVCP:

Specifica tecnica: EN ISO 1716

Sound absorptionvedi

Sistema AVCP:

Specifica tecnica: EN ISO 354

Reaction to firevedi

Sistema AVCP:

Specifica tecnica: EN ISO 9239-1

Sound Insulationvedi

Sistema AVCP:

Specifica tecnica: EN ISO 717-1:2020